Skip to content

HRV1.25 Q Plus

Mechanical Ventilation with Heat Recovery unit (MVHR)
SMALL TO MEDIUM SIZED DWELLINGS

Overview

The enhanced capacity ultra compact HRV1.25 Q Plus continuously running whole-house ventilation unit with heat recovery is independently tested by the BRE.

Combining ultra low power consumption and a highly efficient heat exchanger, the HRV1.25 Q Plus is specifically designed to enhance SAP performance via Appendix Q – yet the unit remains small enough to be easily incorporated into apartments and smaller houses where space is at a premium.

The HRV1.25 Q Plus Range of MVHR unit comes in three different models; our ‘A’ model which is our basic version and our ‘HMB’ & ‘B’ models which are part of our Eco version range.  Each set out to accommodate our customers’ needs.

Recognised and listed in the UK Product Characteristics Database and includes intelligent humidity options through controller options.

Looking for after sales support?

Features & Benefits

  • Extremely compact
  • Extremely low Specific Fan Power; down to 0.53 W/l/s
  • Highly efficient heat exchanger; up to 88%
  • Airflow up to 44 l/s (158 m3/h) at 100 Pa
  • Accepts 125mm diameter ducting, no adaptors required
  • Intelligent frost protection, stepped reduction of supply air rates prevents HRV unit from freezing
  • ISO Coarse 55% (G3) filters as standard with ISO Coarse 60% (G4) as an option
  • Fully adjustable boost overrun timer 0-60 minutes; can be used with non-latching (momentary) switches to prevent unit from being accidentally left in boost mode
  • Setback facility to reduce ventilation where local regulations allow
  • Volt free switching control
  • Removable airtight filter covers for easy filter maintenance (Standard and Eco model)
  • Quick fix mounting bracket
  • IP32 rating
  • Patented features and design
  • Independent fan adjustment
  • Effective in reducing pollutants in the home and improving Indoor Air Quality (IAQ), therefore reducing the risk of Toxic Home Syndrome

Technical Information

Technical Information

Product Codes and Specific Features

Basic Version – A Model:

  • Summer Mode
Product Model Product Code Energy Rating
HRV1.25 Q Plus TP406A Energy Rating A

Eco Versions

Eco HMB Model:

  • Intelligent Summer Bypass & humidity controls
  • SUMMERboost® facility
  • Available in left and right handed configurations
  • Compatible with auralite® HRV (TP518) status indicator and aura-t™ (TP539) controller
  • Fitted with removable filter covers on the front panel
  • Standard – Volt free switching control
  • Optional – Switch live control available with via Relay (TP505)
Product Model Product Code Energy Rating
HRV1.25 Q Plus HMB
Eco auralite® & aura-t™ ready
TP406HMB/544
(left hand config)
Energy Rating A
TP406B/RH
(right hand config)

Eco B Models:

  • Intelligent Summer Bypass & humidity controls
  • SUMMERboost® facility
  • Available in left and right handed configurations
  • Compatible with Eco-aura range; aurastat®, auramode® and aura-t™ (TP536) controllers and auralite® HRV (TP519) status indicator
  • Duct Pre-heater control (requires independent power supply)
  • BMS compatible via RS485 (subject to limitations, additional software requirements and specification with any order)
  • Standard – Volt Free switching and switch live control
Product Model Product Code Energy Rating
HRV1.25 Q Plus B
Eco-aura controls ready
TP416B/LH
(left hand config)
Energy Rating A
TP416B/RH
(right hand config)

Filters (Basic and Eco Versions):

XP40032/099 – ISO Coarse 55% (G3) filters fitted as standard (UK only).
XP46022/099 – ISO Coarse 60% (G4) filters fitted on request (Europe fitted as standard).
XP2011094/099 – ISO Coarse 55% (G3)/ISO ePM1 50% (F7) filters available on request.
XP2011095/099 – ISO Coarse 60% (G4)/ISO ePM1 50% (F7) filters available on request.

Standards

Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation and BRE 398.
SAP Appendix Q tested
Exceeds requirements of Building Regulations Approved Document L (England & Wales).
EU RoHS Directive compliant.
Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Electrical Safety:
2006/95/EC (LVD), 2004/108/EC (EMC),  EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/A1:2004.
CE and UKCA Marked.

Specification

Dimensions: 600mm wide x 430mm high (excluding ports) x 285mm deep (295mm with mounting bracket).


Weight: 16kg
Finish: White Paint (RAL9016 Semi-gloss Traffic White).

Materials;
Housing: Zintec sheet steel housing, powder coated white
Internals: Expanded polypropylene (EPP)
Heat exchanger: Polystyrene
Internal insulation: Closed cell foamed Nitrile rubber, class ‘O’ fire rating
Standard filters: Grade ISO Coarse 55% (G3) synthetic filters
Guarantee period: 3 years (UK only).
Electrical: 230V ~ 50/60Hz, 3A fuse.
Installation: To be installed accordance with the relevant and applicable building regulations.
Maintenance: Service and filter replacement subject to local environment – see product manual.
Acoustics: Full acoustic data.

Performance

Exhaust terminal configuration*
Fan speed setting
Specific fan power (W/l/s)
Heat exchange efficiency (%)
Specific fan power (W/l/s)
Heat exchange efficiency (%)
2009
2012
Kitchen + 1 additional wet room
100% variable
0.59
88%
0.68
87%
Kitchen + 2 additional wet rooms
100% variable
0.67
87%
0.9
85%
Kitchen + 3 additional wet rooms
100% variable
0.82
85%
1.21
84%
Kitchen + 4 additional wet rooms
100% variable
1.04
84%

Figures taken from the BRE Test Results.
*Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance requirements.

Performance Curve

*@FID (0 Pa)
All units offer 100% variable speed control.

Acoustic Data

Product
% of Max flow
Airflow
dB(A) @ 3m Hemispherical
dB(A) @ 3m Spherical
Induct Inlet
Induct Outlet
Casing Breakout
Casing Breakout
HRV1.25 Q Plus Eco
40%
22l/s @ 10Pa
28
41
20
17
61%
34l/s @ 23Pa
36
49
28
25
100%
56l/s @ 50Pa
43
57
36
33

All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.

Documentation

Resources

Manuals and Documentation

Product Manual - auralite® HRV (TP519)

340.24 KB (English)
Download

URL for Product Manual - auralite® HRV (TP519) copied to clipboard.

Product Manual - aura-t™ HMB Model

3.83 MB (English)
Download

URL for Product Manual - aura-t™ HMB Model copied to clipboard.

Product Manual - aura-t™ B Model GBR

4.95 MB (English)
Download

URL for Product Manual - aura-t™ B Model GBR copied to clipboard.

Product Manual - auramode Constant Flow Unit Controller BAR units

8.38 MB (English)
Download

URL for Product Manual - auramode Constant Flow Unit Controller BAR units copied to clipboard.

HRV AV Mounting Kits - Fitting Instruction

731.35 KB (English)
Download

URL for HRV AV Mounting Kits - Fitting Instruction copied to clipboard.

Product Manual - Boxed Relay 5A (TP505)

575.63 KB (English)
Download

URL for Product Manual - Boxed Relay 5A (TP505) copied to clipboard.

MVHR/HRV Drain Conversion - Datasheet

334.56 KB (English)
Download

URL for MVHR/HRV Drain Conversion - Datasheet copied to clipboard.

Catalogues

Ventilation Systems Catalogue

18.75 MB (English)
Download

URL for Ventilation Systems Catalogue copied to clipboard.

Ventilation Product Overview Brochure

2.81 MB (English)
Download

URL for Ventilation Product Overview Brochure copied to clipboard.

HRV1.25 Q Plus - Catalogue Page

408.04 KB (English)
Download

URL for HRV1.25 Q Plus - Catalogue Page copied to clipboard.

Case Studies

Case Study: HRV Q Plus units and ducting, London

(English)
Visit URL

URL for Case Study: HRV Q Plus units and ducting, London copied to clipboard.

Specifier Text

HRV1.25 Q Plus - Specifiers Text (TP406A)

196.1 KB (English)
Download

URL for HRV1.25 Q Plus - Specifiers Text (TP406A) copied to clipboard.

HRV1.25 Q Plus - Specifiers Text (TP406HMB)

197.12 KB (English)
Download

URL for HRV1.25 Q Plus - Specifiers Text (TP406HMB) copied to clipboard.

HRV1.25 Q Plus - Specifiers Text (TP416B)

198.14 KB (English)
Download

URL for HRV1.25 Q Plus - Specifiers Text (TP416B) copied to clipboard.

Acoustic Information

HRV1.25 Q Plus - Acoustic Performance

559 KB (English)
Download

URL for HRV1.25 Q Plus - Acoustic Performance copied to clipboard.

Sound Attenuating Ventilation

385.72 KB (English)
Download

URL for Sound Attenuating Ventilation copied to clipboard.

User Guides

What is MVHR?

(English)
Visit URL

URL for What is MVHR? copied to clipboard.

Top 10 Install Problems - Guide

2.65 MB (English)
Download

URL for Top 10 Install Problems - Guide copied to clipboard.

NHBC Standards 2020 - Chapter 8.1 (Internal services)

748.83 KB (English)
Download

URL for NHBC Standards 2020 - Chapter 8.1 (Internal services) copied to clipboard.

DVCG (Domestic Ventilation Compliance Guide)

1.83 MB (English)
Download

URL for DVCG (Domestic Ventilation Compliance Guide) copied to clipboard.

How to change MVHR Filters

6.5 MB (English)
Download

URL for How to change MVHR Filters copied to clipboard.

Condensation Drain - User Guide/Installer Guide

244.96 KB (English)
Download

URL for Condensation Drain - User Guide/Installer Guide copied to clipboard.

MVHR/MEV Running Costs

165.87 KB (English)
Download

URL for MVHR/MEV Running Costs copied to clipboard.

HRV - Spares Matrix

958.34 KB (English)
Download

URL for HRV - Spares Matrix copied to clipboard.

HRV Q Plus - Port Configurations/Airflow Direction (Vertical Units)

2.43 MB (English)
Download

URL for HRV Q Plus - Port Configurations/Airflow Direction (Vertical Units) copied to clipboard.

HRV Q Plus - User Guide

835.61 KB (English)
Download

URL for HRV Q Plus - User Guide copied to clipboard.

aurastat® - Defaults Guide

147.38 KB (English)
Download

URL for aurastat® - Defaults Guide copied to clipboard.

aura-t™ - Changing from integral to remote

1.18 MB (English)
Download

URL for aura-t™ - Changing from integral to remote copied to clipboard.

Fitting Instructions - HMB aura-t Upgrade Kit

1.06 MB (English)
Download

URL for Fitting Instructions - HMB aura-t Upgrade Kit copied to clipboard.

Connecting a controller to a MVHR Unit - User Guide

129.89 KB (English)
Download

URL for Connecting a controller to a MVHR Unit - User Guide copied to clipboard.

HRV Vertical Mounting Information - User Guide

611.71 KB (English)
Download

URL for HRV Vertical Mounting Information - User Guide copied to clipboard.

aura-t™ - Commissioning Procedure (HMB & B Models)

3.37 MB (English)
Download

URL for aura-t™ - Commissioning Procedure (HMB & B Models) copied to clipboard.

Fault Finding

HRV Q Plus - Fault Finding (HMB) post 1/1/2019

4.16 MB (English)
Download

URL for HRV Q Plus - Fault Finding (HMB) post 1/1/2019 copied to clipboard.

HRV Q Plus – Fault Finding (HMB pre 1/1/2019)

3.22 MB (English)
Download

URL for HRV Q Plus – Fault Finding (HMB pre 1/1/2019) copied to clipboard.

HRV Q Plus - Fault Finding (B Models)

1.77 MB (English)
Download

URL for HRV Q Plus - Fault Finding (B Models) copied to clipboard.

HRV Q Plus - Fault Finding (MB)

2.96 MB (English)
Download

URL for HRV Q Plus - Fault Finding (MB) copied to clipboard.

HRV Q Plus - Fault Finding (ABS)

2.25 MB (English)
Download

URL for HRV Q Plus - Fault Finding (ABS) copied to clipboard.

HRV Q Plus - Fault Finding (ABD)

2.28 MB (English)
Download

URL for HRV Q Plus - Fault Finding (ABD) copied to clipboard.

HRV Q Plus - Fault Finding (A)

1.62 MB (English)
Download

URL for HRV Q Plus - Fault Finding (A) copied to clipboard.

Calculators

Part F Calculator (UK only)

30.75 KB (English)
Download

URL for Part F Calculator (UK only) copied to clipboard.

Test Results

Product Characteristics Database (PCDB) – HRV1.25 Q Plus ECO Test Results

(English)
Visit URL

URL for Product Characteristics Database (PCDB) – HRV1.25 Q Plus ECO Test Results copied to clipboard.

URL

How to identify which HRV (MVHR) you have

(English)
Visit URL

URL for How to identify which HRV (MVHR) you have copied to clipboard.

The CPD Certification Service

(English)
Visit URL

URL for The CPD Certification Service copied to clipboard.

HRV Filters - Buy online

(English)
Visit URL

URL for HRV Filters - Buy online copied to clipboard.

Manuals and Documentation (Obsolete)

Product Manual - HRV1, 1.25, 1.5, 1.75, 2, 2.75 & 3 A, ABS (Obsolete)

4.97 MB (English)
Download

URL for Product Manual - HRV1, 1.25, 1.5, 1.75, 2, 2.75 & 3 A, ABS (Obsolete) copied to clipboard.

Product Manual - HRV1.25, 1.75, 2 & 3 MB (Obsolete)

3.84 MB (English)
Download

URL for Product Manual - HRV1.25, 1.75, 2 & 3 MB (Obsolete) copied to clipboard.

Product Manual - HRV1.25, 1.75, 2 & 3 (TP406HMB, TP404HMB, TP401HMB, TP402HMB) - (Obsolete)

3.66 MB (English)
Download

URL for Product Manual - HRV1.25, 1.75, 2 & 3 (TP406HMB, TP404HMB, TP401HMB, TP402HMB) - (Obsolete) copied to clipboard.

Quote and Order Form

Request for Information (R.F.I.) Form

129.12 KB (English)
Download

URL for Request for Information (R.F.I.) Form copied to clipboard.

Product Fiches

BIM Models

MVHR Vertical - BIM Model

3.57 MB (English)
Download

URL for MVHR Vertical - BIM Model copied to clipboard.

Videos

Video: How to replace filters in a Titon MVHR unit

(English)
Visit URL

URL for Video: How to replace filters in a Titon MVHR unit copied to clipboard.

Video: MVHR Unit - Motor Replacement Guide: HRV 1, 1.25, 1.3 and 1.35

(English)
Visit URL

URL for Video: MVHR Unit - Motor Replacement Guide: HRV 1, 1.25, 1.3 and 1.35 copied to clipboard.

Video: Mechanical Ventilation with Heat Recovery - Part F: System 4 Loft

(English)
Visit URL

URL for Video: Mechanical Ventilation with Heat Recovery - Part F: System 4 Loft copied to clipboard.

Video: MVHR - How it Works: Summer Bypass

(English)
Visit URL

URL for Video: MVHR - How it Works: Summer Bypass copied to clipboard.

Video: MVHR - How it Works: Summer Mode

(English)
Visit URL

URL for Video: MVHR - How it Works: Summer Mode copied to clipboard.

Video: MVHR - How it Works: SUMMERboost®

(English)
Visit URL

URL for Video: MVHR - How it Works: SUMMERboost® copied to clipboard.

Video: MVHR - How it Works: Boost Speed with Overrun Timer

(English)
Visit URL

URL for Video: MVHR - How it Works: Boost Speed with Overrun Timer copied to clipboard.

Video: MVHR - How it Works: Setback Speed

(English)
Visit URL

URL for Video: MVHR - How it Works: Setback Speed copied to clipboard.

Video: Mechanical Ventilation with Heat Recovery - Part F: System 4

(English)
Visit URL

URL for Video: Mechanical Ventilation with Heat Recovery - Part F: System 4 copied to clipboard.

CE Certificate of Conformity

HRV1.25 Q Plus Eco HMB Certificate of Conformity (TP406HMB-RH-T)

483.47 KB (English)
Download

URL for HRV1.25 Q Plus Eco HMB Certificate of Conformity (TP406HMB-RH-T) copied to clipboard.

HRV1.25 Q Plus - Certificate of Conformity (TP416B-HUN-RH)

659.14 KB (English)
Download

URL for HRV1.25 Q Plus - Certificate of Conformity (TP416B-HUN-RH) copied to clipboard.

HRV1.25 Q Plus - Certificate of Conformity (TP416B-FAD-LH)

813.78 KB (English)
Download

URL for HRV1.25 Q Plus - Certificate of Conformity (TP416B-FAD-LH) copied to clipboard.

HRV1.25 Q Plus - Certificate of Conformity (TP416B-BEL-RH)

659.14 KB (English)
Download

URL for HRV1.25 Q Plus - Certificate of Conformity (TP416B-BEL-RH) copied to clipboard.

HRV1.25 Q Plus - Certificate of Conformity (TP416B-BEL-LH)

659.14 KB (English)
Download

URL for HRV1.25 Q Plus - Certificate of Conformity (TP416B-BEL-LH) copied to clipboard.

HRV1.25 Q Plus - Certificate of Conformity (TP406HMB-BEL-RH)

813.77 KB (English)
Download

URL for HRV1.25 Q Plus - Certificate of Conformity (TP406HMB-BEL-RH) copied to clipboard.

HRV1.25 Q Plus - Certificate of Conformity (TP406HMB-BEL)

813.76 KB (English)
Download

URL for HRV1.25 Q Plus - Certificate of Conformity (TP406HMB-BEL) copied to clipboard.

HRV1.25 Q Plus - Certificate of Conformity (TP406HMB-544-T)

483.47 KB (English)
Download

URL for HRV1.25 Q Plus - Certificate of Conformity (TP406HMB-544-T) copied to clipboard.

HRV1.25 Q Plus - Certificate of Conformity (TP416B-RH)

659.14 KB (English)
Download

URL for HRV1.25 Q Plus - Certificate of Conformity (TP416B-RH) copied to clipboard.

HRV1.25 Q Plus Certificate of Conformity (TP416B-LH)

659.14 KB (English)
Download

URL for HRV1.25 Q Plus Certificate of Conformity (TP416B-LH) copied to clipboard.

HRV1.25 Q Plus - Certificate of Conformity (TP406HMB-RH)

813.76 KB (English)
Download

URL for HRV1.25 Q Plus - Certificate of Conformity (TP406HMB-RH) copied to clipboard.

HRV1.25 Q Plus - Certificate of Conformity (TP406HMB-LH)

813.76 KB (English)
Download

URL for HRV1.25 Q Plus - Certificate of Conformity (TP406HMB-LH) copied to clipboard.

HRV1.25 Q Plus - Certificate of Conformity (TP406A-544)

1.1 MB (English)
Download

URL for HRV1.25 Q Plus - Certificate of Conformity (TP406A-544) copied to clipboard.

UKCA Certificate of Conformity

HRV2.85 Q Plus EcoAura - UKCA Certificate of Conformity (TP417B-LH)

792.54 KB (English)
Download

URL for HRV2.85 Q Plus EcoAura - UKCA Certificate of Conformity (TP417B-LH) copied to clipboard.

HRV1.25 Q Plus EcoAura - UKCA Certificate of Conformity (TP416B-RH)

660.45 KB (English)
Download

URL for HRV1.25 Q Plus EcoAura - UKCA Certificate of Conformity (TP416B-RH) copied to clipboard.

HRV1.25 Q Plus EcoAura - UKCA Certificate of Conformity (TP416B-LH)

660.46 KB (English)
Download

URL for HRV1.25 Q Plus EcoAura - UKCA Certificate of Conformity (TP416B-LH) copied to clipboard.

HRV1.25 Q Plus EcoAura - UKCA Certificate of Conformity (TP416B-FAD-LH)

815.17 KB (English)
Download

URL for HRV1.25 Q Plus EcoAura - UKCA Certificate of Conformity (TP416B-FAD-LH) copied to clipboard.

HRV1.25 Q Plus Eco HMB - UKCA Certificate of Conformity (TP406HMB-RH-T)

484.8 KB (English)
Download

URL for HRV1.25 Q Plus Eco HMB - UKCA Certificate of Conformity (TP406HMB-RH-T) copied to clipboard.

HRV1.25 Q Plus Eco HMB - UKCA Certificate of Conformity (TP406HMB-RH)

815.17 KB (English)
Download

URL for HRV1.25 Q Plus Eco HMB - UKCA Certificate of Conformity (TP406HMB-RH) copied to clipboard.

HRV1.25 Q Plus Eco HMB - UKCA Certificate of Conformity (TP406HMB-544-T)

484.8 KB (English)
Download

URL for HRV1.25 Q Plus Eco HMB - UKCA Certificate of Conformity (TP406HMB-544-T) copied to clipboard.

HRV1.25 Q Plus Eco HMB - UKCA Certificate of Conformity (TP406HMB-544)

815.17 KB (English)
Download

URL for HRV1.25 Q Plus Eco HMB - UKCA Certificate of Conformity (TP406HMB-544) copied to clipboard.

Similar Products

Similar Products

Contact one of our experts

Whatever your query, please get in touch.